Model No.: T6

Powerful scars removal USA tube white color 40w Fractional CO2 Laser Machine Vaginal Tightening<br

Powerful scars removal USA tube white color 40w Fractional CO2 Laser Machine Vaginal Tightening
 

 

Wavelength

10.64um

Power Output

1-40W

Spot Size

0.12mm & 1.25mm (adjustable)

Spot Density

Up to 102400 dot

RF tube USA tube


 

What’s CO2 laser?
Fractionated CO2 laser technology has allowed physicians to resurface 
patients with a lower rate of complications than nonfractionated ablative 
laser treatment. Unfortunately, adverse effects can still occur even with 
the best technology and physician care. Complication prevention, detection, 
and treatment are an important part of a physician's ability to provide the 
best result when treating a patient with fractionated CO2 resurfacing.
 
The development of CO2 lasers was motivated by the desire to achieve 
excellent results while maintaining a favorable side-effect profile. Although significant side effects are relatively uncommon, 
they do occur and occasionally may be severe. Understandably, cosmetic 
surgery patients have less tolerance of side effects than patients undergoing 
medically indicated procedures. The astute surgeon will learn to prevent, 
promptly recognize, and treat these side effects.

 
Prevention
Complication prevention should be kept in mind throughout the treatment 
process. During the initial consultation, the patient should be evaluated for 
factors that may predispose that patient to developing a side effect. A history 
of poor wound healing, keloids, or hypertrophic scarring may be an indication 
to avoid aggressive skin resurfacing. Patients who tan easily may be at risk 
for hyperpigmentation after their laser session. An individual with extensive sun-damaged skin may need full-face treatment (as opposed to partial treatment) to ensure cosmetic blending 
of skin color. In addition, patients with a compromised immune system are at 
greater risk of infection. A detailed history obtained during the consultation is 
vital to predicting these risks and selecting suitable candidates.
 
Proper skin care postprocedure is vital to achieving quick healing while 
minimizing the risk of infection. Although an in-depth exploration of skin care is beyond the scope of this article, specialized 
skin care involving the use of gentle cleansing along with protective ointments 
and/or dressings, antibiotics, and antivirals are typically the basis of postoperative 
ablative fractional resurfacing care.
 
Go to Infection
An intact skin barrier is the best layer of defense against infection. By definition, 
fractionated ablative CO2 laser resurfacing perforates the skin barrier allowing 
for a potential infection postprocedure. The pathologic organisms that may 
infect the skin include bacteria, fungi, and viruses. The most common cause 
of scarring is postoperative infection, which usually presents several days 
postoperatively as a localized area of delayed healing (Fig. 1). Inexperienced 
or inattentive surgeons as well as patients may find it difficult to distinguish 
infection from the normal healing process. When an infection is suspected, 
it is advised to promptly perform microbiologic culture testing to identify the 
organism and determine its sensitivity to treatment.
 
Specification or technical parameters
 
The CO2 Fractional laser is a kind of minimal invasive surgery, which lies 
in between invasive and non-invasive treatment. It has not only rapid and evident results like invasive 
treatment but also less side effects and shorter recovery time like the non-invasive treatment. It is to evenly mark with tiny holes, and then there will 
be a series of biochemical reactions inside the skin, to Lift the skin and 
remove speckles and pigments.
 
Advantages
Powerful software adjusts parameter easily. Multiple graphics and 
scanning mode for your selection. Moreover, the graphics could be two-way adjusted;
Continuous, super pulse, fractional different Operation Modes, There is a wider use in clinical application;
Focal spot diameter and interval are adjustable. Patient’s unique needs can be met during treatment;
The best  USA RF laser tube, Stable performance, high effective, No consumable costs;
Inhale and deflate air system;
 
 
Treatment

bigPhoto
 Mr. Karen Liu

Tel: 86-10-57212057
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Beijing Jontelaser Technology Company [China (Mainland)]


Business Type:Manufacturer
City: Beijing
Province/State: Beijing
Country/Region: China (Mainland)

You May Like:

Product (136)